IML: Attn: Tom Scott (was re: Gauges )
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
IML: Attn: Tom Scott (was re: Gauges )
- From: "Dick Benjamin" <dickb@xxxxxxxxx>
- Date: Wed, 14 Dec 2005 09:30:11 -0800
No, by far the most likely culprit is the sending unit in the tank. If your
temp and oil pressure gauges are operating OK, then your gauge regulator
(AKA voltage limiter) is fine.
Check to see that the tank is securely grounded, and that the wire from the
tank sender to the dash unit is connected at the tank. If both of these
things are OK, then it's time to investigate the sender in the tank.
Dick Benjamin
-----Original Message-----
Tom Scott
Sent: Wednesday, December 14, 2005 5:17 AM
Subject: Re: IML: Gauges
Please excuse my ignorance but I've got a 60 Imperial with an inop fuel
guage. Am I correct to assume that the problem is most likely a bad
limiter?
Tom